Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Equine Vet Sci ; 136: 105074, 2024 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38648909

RESUMEN

The aim of this study was to evaluate the intraocular pressure (IOP) measurements obtained from first, second, and third probe-cornea touch (PCT) and compare them with the average of six PCTs using two rebound tonometers in horses. This study enrolled a total of thirty-eight stallions, comprising of 24 Arabian horses and 14 cross-breeds (with an average age of 8 ± 3 years). The IOP measurements of first, second, and third, as well as the average of six PCTs were obtained using either Tonovet (TV) or Tonovet Plus (TV+) rebound tonometers. The mean differences (95% limits of agreement) between the average of six PCTs and the first, second, and third PCTs were 0.1 (-4.8 to 5), 0.2 (-4.8 to 4.5), and 0.2 (-3.6 to 4.0) mmHg with TV, respectively. With TV+, the differences were 0.3 (-6.6 to 7.2), 1.1 (-8.6 to 10.8), and -0.2 (-3.6 to 4.0) mmHg, respectively. Compared to the average of six PCTs, only 89.5%, 92.1%, and 97.4% of IOP measurements obtained from TV and 78.9%, 73.3%, and 65.8% of IOP measurements obtained from TV+ were within 4 mmHg of the average of six PCTs for first, second, and third PCTs, respectively. In conclusion, the measurement of IOP in the first PCT achieved best agreement with the IOP measurement of six average PCTs. Therefore, the first PCT could be considered as an alternative option for measuring IOP in horses when obtaining an average of six PCTs is not feasible.

2.
N Z Vet J ; 71(5): 251-258, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37306141

RESUMEN

AIMS: To compare intraocular pressure (IOP) measurements obtained in rabbits using rebound (TV) and applanation (TPV) tonometers with four different methods of physical restraint. METHODS: A total of 20 New Zealand White rabbits (40 eyes) were included in this study. IOP readings were obtained from both eyes using the two different tonometers. The rabbits were placed on a table and restrained by wrapping in a cloth (Method I), by scruffing with rear support (Method II), by wrapping in a cloth and cupped in the hands (Method III), or by a box restrainer (Method IV). RESULTS: The mean IOP measurement obtained by TPV was higher than that obtained with the TV for all handling methods. Mean differences (TV-TPV, in mmHg) in IOP were -5.3 (95% Cl = -6.5 to -4.1) for Method 1, -4.7 (95% Cl = -6.2 to -3.29) for Method II, -4.9 (95% Cl = -6.2 to -3.7) for Method III and -7.6 (95% Cl = -9.2 to -5.9) for Method IV. Using the TV tonometer, mean IOP for Method IV was higher than for Method I (mean difference 2.1 (95% Cl = 1.1-3.1)), whereas using the TPV tonometer, mean IOP for Method IV was significantly higher than Method I, II, and III (mean differences: 4.4 (95% Cl = 2.6-5.9), 3.7 (95% Cl = 2-5.3) and 3.8 (95% Cl = 2-5.4), respectively). According to Bland-Altman plots, IOP readings for TPV tended to be higher than those for TV with all handling methods, but with a lack of agreement. The mean difference and 95% limits of agreement for the differences between TV and TPV were -5.4 mmHg (-12.5-1.9 mmHg), -4.7 mmHg (-12.9-3.5 mmHg), -4.9 mmHg (-12-2.2 mmHg), and -7.5 mmHg (-17.4-2.3 mmHg), with Methods I, II, III, and IV, respectively. Comparing TV and TPV, only 7.5%, 12.5%, 27.5%, and 15% of IOP measurements from 20 rabbits were within the range considered clinically acceptable for IOP (± 2 mmHg) for Method I, II, III, and IV, respectively. CONCLUSION AND CLINICAL RELEVANCE: In conclusion, the physical restraint method should be recorded when IOP is measured in rabbits, and TV and TPV tonometers cannot be used interchangeably (high bias and low proportion of measurements within ± 2 mmHg).


Asunto(s)
Presión Intraocular , Tonometría Ocular , Animales , Conejos , Tonometría Ocular/instrumentación , Tonometría Ocular/métodos , Tonometría Ocular/veterinaria , Restricción Física , Masculino , Femenino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...